![]() Scintillation Counting System
The ST360W is a versatile, general purpose counter/timer for use with either a scintillation or GM detector. The unit features a large, 6-digit LED display with selection for counts, time, countrate, high voltage or alarm level. USB and serial outputs are included for connecting to an optional PC or Macintosh computer for data transfer and automated operation if required. A fully regulated high voltage power supply with digital control is used to power the scintillator or GM detector and set the energy range or operating plateau. Various operating modes include preset time, preset alarm level and digital ratemeter. A remote position allows operation with a computer if required. Specifications Inputs: MHV connector. Accepts standard scintillation detectors with single HV/signal cable. Built-in preamplifier. BNC connector for GM detector. Energy Range: <20kev to>2MeV Resolving Time: Less than 1µsec. High voltage: 0 to +1200 volts, digitally selectable in 20 volt increments. Display: 6-decade LED, 1 in. numerals displays counts, preset counts. time, preset time, CPM, CPS, alarm level, and high voltage. Modes: Digital Counter or Digital Ratemeter, 999999 capacity. Count for preset time 1-900000 sec or continuous, counts/min., counts/sec., set alarm level 0-999999, set high voltage 0-1200v, and computer controlled. Audio: Piezo alerter for countrate and preset alarm level. Data Link : USB 2.0, DB-9 connectors accepts RS-232 serial cable for IBM and Macintosh computers. Power: Input 9 volt DC, at 500mA from AC line/charger. Specify 110-120, 220-240 VAC at time of order. Dimensions: 12 in. W, x 8 in. H, x 4.5 in. D. Order information:ST360W: Specify 110 or 220VAC operation. Detectors:SP78W-1: Well scintillation detector with stand, LS2000 lead shield and cable. SPA38: Cylindrical scintillation detector with GMS38 sample holder, LS038 lead shield and cable. GP35: End window GM detector with sample holder and cable. | ![]() |
Scintillation Well Detector System
The ST360W is a versatile, general purpose counter/timer for use with either a scintillation or GM detector. The unit features a large, 6-digit LED display with selection for counts, time, countrate, high voltage or alarm level. USB and serial outputs are included for connecting to an optional PC or Macintosh computer for data transfer and automated operation if required. | |
Single Channel Analyzer and Processor
The ST450 Scintillation SCA provides a convenient interface between a scintillation detector and counter/timer for detecting gamma rays over a defined energy range. Front panel controls allow selection of an energy window so that only gamma-rays within a specific energy range are counted. The unit contains all of the necessary support for connecting a scintillation detector and includes high voltage and built-in preamplifier/amplifier. |